Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
J Adhes Dent ; 26(1): 103-116, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38602234

RESUMO

PURPOSE: To investigate the antibacterial effects of Terminalia catappa Linn (TCL) leaf extracts at different concentrations and the effects of these extracts used as primers on the long-term adhesive properties of two universal adhesives. MATERIALS AND METHODS: After extract preparation, the antimicrobial and antibacterial activities of TCL against Streptococcus mutans (UA 159) were assessed in microdilution assays to provide the minimal inhibitory concentration (MIC) and minimal bactericidal concentration (MBC). Additionally, to provide quantitative data on the ability of TCL extract to reduce cell viability, colony forming units (CFU) were counted. To examine adhesive properties, 288 human molars were randomly assigned to 32 experimental conditions (n = 9) according to the following variables: (1) treatment agent: negative control (untreated surface), and primers at concentrations of 1xMIC, 5xMIC, and 10xMIC; (2) adhesives: Scotchbond Universal (SBU) and Futurabond Universal (FBU); (3) adhesive strategy: etch-and-rinse (ER) or self-etch (SE); and (4) storage time: 24 h or after 2 years. Primers were applied for 60 s, upon which the teeth were incrementally restored and sectioned into adhesive-dentin bonded sticks. These were tested for microtensile bond strength (µTBS) and nanoleakage (NL) after 24-h and 2-year water storage, as well as in-situ degree of conversion (DC) at 24 h. The chemical profile of the hybrid layer was determined via micro-Raman spectroscopy. Biofilm assay data were analyzed using the Kruskal-Wallis test; the pH of culture media and the chemical profile were analyzed by one-way ANOVA. The adhesive properties (µTBS, NL, DC) were evaluated using a four-way ANOVA and Tukey's test. Significance was set at 5%. RESULTS: Similar values of MIC and MBC were observed (2 mg/ml), showing bactericidal potential. CFU analysis demonstrated that concentrations of 5xMIC and 10xMIC significantly inhibited biofilm formation (p < 0.001). The application of the TCL primer at all concentrations significantly increased the immediate µTBS and DC, and decreased the immediate NL values when compared to the control group (p < 0.05), regardless of the adhesive and adhesive strategies. Despite an increase in the NL values for all groups after 2 years (p > 0.05), in groups where the TCL primer was applied, the µTBS remained constant after 2 years for both adhesives, while a decrease in the µTBS was observed in the control groups (p < 0.05). Usually, 10xMIC showed better results than 1xMIC and 5xMIC (p < 0.05). The application of TCL promoted cross-linking; cross-linking rates increased proportionally to the concentration of TCL (p < 0.05). CONCLUSION: Primers containing TCL promoted bactericidal and bacteriostatic action, as well as cross-linking with dentin, while maintaining the adhesive properties of the adhesive-dentin interface after 2 years of water storage.


Assuntos
Colagem Dentária , Terminalia , Humanos , Cimentos Dentários/farmacologia , Cimentos Dentários/química , Adesivos Dentinários/farmacologia , Adesivos Dentinários/química , Resinas Compostas/química , Dentina , Resistência à Tração , Cimentos de Resina/farmacologia , Cimentos de Resina/química , Água/química , Antibacterianos/farmacologia , Teste de Materiais
2.
J Adhes Dent ; 25(1): 257-266, 2023 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-38116811

RESUMO

PURPOSE: This study evaluated the long-term push-out bond strength (PBS) and nanoleakage (NL) of universal adhesives with different photo-initiator systems in the root canals of teeth in which fiber posts were luted. MATERIALS AND METHODS: One-hundred twenty endodontically treated human premolars were randomly divided into 12 groups based on the following factors: adhesives (Scotchbond Universal [SBU], Ambar Universal [AMB], and Ambar Universal APS [AMB-APS]); adhesive strategy (etch-and-rinse and self-etch), and time of testing (immediately vs after 2 years). The posts were cemented, sectioned into slices, tested for PBS at 0.5 mm/min, and examined for NL using scanning electron microscopy immediately thereafter or after 2 years of water storage. Data were evaluated using a four-way ANOVA (root thirds vs time vs universal adhesive vs adhesive strategies) and Tukey's test (α = 5%). RESULTS: For both evaluation times, AMB-APS demonstrated no significant difference in the PBS or NL when different radicular thirds were compared (p > 0.05). However, for SBU and AMB, the cervical third demonstrated higher PBS and lower NL than those of the apical third at both time points (p < 0.0001). AMB-APS exhibited higher PBS and lower NL in the apical third in comparison with SBU and AMB (p < 0.0001). SBU and AMB displayed a significant decrease in the PBS and increased NL after 2 years (p < 0.0001), whereas AMB-APS demonstrated no significant signs of degradation even after 2 years of water storage (p > 0.05). CONCLUSION: Independent of the root third evaluated, the universal adhesive containing APS photo-initiator system demonstrated bonding stability at the adhesive interface between the root canal and fiber posts, even after 2 years of water storage.


Assuntos
Colagem Dentária , Técnica para Retentor Intrarradicular , Humanos , Cimentos Dentários/química , Metacrilatos/química , Cimentos de Resina/química , Água , Dentina , Colagem Dentária/métodos , Teste de Materiais , Adesivos Dentinários/química , Adesivos
3.
J Appl Oral Sci ; 31: e20230216, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37909527

RESUMO

OBJECTIVE: Despite the availability of in-office bleaching gels with a 6% concentration of hydrogen peroxide (HP), these gels have not been evaluated in younger patients. They are commercially available with a tip, associated or not with a brush, where the tip with a brush spreads the gel over the entire surface to have a smaller thickness (thin layer) since the manufacturers indicate the application of a thin layer of gel. This randomized, split-mouth, double-blind clinical trial evaluated the efficacy of in-office bleaching with 6% HP in adolescents using different application tips, as well tooth sensitivity (TS) and aesthetic self-perception. METHODOLOGY: Sixty participants were randomized for 6% HP self-mixing bleaching gel tip design: without brush and with brush. In-office bleaching was performed in 3 sessions of 50 minutes. Color change was evaluated using a digital spectrophotometer (ΔE ab , ΔE 00 , and ΔWI D ) and color guide (ΔSGU), the absolute risk and intensity of TS with a visual analogue scale and aesthetic self-perception with the oral aesthetic scale (a=0.05). RESULTS: The groups achieved similar bleaching regardless of the application tip (p>0.05). However, only for ΔWI D , a significant mean difference (MD) was observed in the third week (MD 2.3; 95% CI 1.2 to 3.3; p < 0.001) and at one month (MD 1.6; 95% CI 0.6 to 2.6; p < 0.03) favoring the tip without brush. Regarding TS, 45% in the tip-without-brush group and 33% in the tip-with-brush group reported TS (odds ratio 0.61; 95% CI 0.29 to 1.28; p<0.02), with low TS intensity (MD 0.05; 95% CI -0.06 to 0.17; p>0.36). All patients reported improved aesthetic self-perception after bleaching (MD -1.3; 95% -1.8 to -0.9; p<0.001). CONCLUSIONS: Regardless of the tip used bleaching with 6% HP achieved a bleaching efficacy and improved the aesthetic self-perception. However, a lower risk of TS for application using the tip with brush was observed.


Assuntos
Sensibilidade da Dentina , Clareadores Dentários , Clareamento Dental , Humanos , Adolescente , Peróxido de Hidrogênio , Resultado do Tratamento , Géis
4.
J. appl. oral sci ; 31: e20230216, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1521084

RESUMO

Abstract Despite the availability of in-office bleaching gels with a 6% concentration of hydrogen peroxide (HP), these gels have not been evaluated in younger patients. They are commercially available with a tip, associated or not with a brush, where the tip with a brush spreads the gel over the entire surface to have a smaller thickness (thin layer) since the manufacturers indicate the application of a thin layer of gel. Objective This randomized, split-mouth, double-blind clinical trial evaluated the efficacy of in-office bleaching with 6% HP in adolescents using different application tips, as well tooth sensitivity (TS) and aesthetic self-perception. Methodology Sixty participants were randomized for 6% HP self-mixing bleaching gel tip design: without brush and with brush. In-office bleaching was performed in 3 sessions of 50 minutes. Color change was evaluated using a digital spectrophotometer (ΔE ab , ΔE 00 , and ΔWI D ) and color guide (ΔSGU), the absolute risk and intensity of TS with a visual analogue scale and aesthetic self-perception with the oral aesthetic scale (a=0.05). Results The groups achieved similar bleaching regardless of the application tip (p>0.05). However, only for ΔWI D , a significant mean difference (MD) was observed in the third week (MD 2.3; 95% CI 1.2 to 3.3; p < 0.001) and at one month (MD 1.6; 95% CI 0.6 to 2.6; p < 0.03) favoring the tip without brush. Regarding TS, 45% in the tip-without-brush group and 33% in the tip-with-brush group reported TS (odds ratio 0.61; 95% CI 0.29 to 1.28; p<0.02), with low TS intensity (MD 0.05; 95% CI -0.06 to 0.17; p>0.36). All patients reported improved aesthetic self-perception after bleaching (MD -1.3; 95% -1.8 to -0.9; p<0.001). Conclusions Regardless of the tip used bleaching with 6% HP achieved a bleaching efficacy and improved the aesthetic self-perception. However, a lower risk of TS for application using the tip with brush was observed.

5.
Polymers (Basel) ; 14(13)2022 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-35808746

RESUMO

This paper evaluates the effect of an additional hydrophobic resin coat (extra HL) associated with universal adhesives on sound and eroded dentin and evaluated immediately or after 2 years of water storage to improve the microtensile bond strength (µTBS) and nanoleakage (NL) when compared to the use of universal adhesives only. Sixty-four molars were assigned to eight groups using the following combinations: 1. dentin substrate, including sound and eroded dentin; 2. treatment, including the control and extra HL and storage time (immediately and after two-years of storage). Two universal adhesives (Prime & Bond Active or Scotchbond Universal) were evaluated. Before restoration, half of the teeth were subjected to soft-drink erosion. Composite buildups were bonded; specimens were stored (37 °C/24 h), sectioned into resin−dentin bonded sticks and tested for microtensile bond strength and nanoleakage using SEM (immediately and after two-years of storage). Three-way ANOVA and Tukey's test (α = 0.05%) were used. In the immediate testing, the application of extra HL did not increase microtensile bond strength values compared with the control group in either substrate (p > 0.05). However, extra HL significantly decreased nanoleakage values when applied to eroded and sound dentin (p = 0.0001). After two years, the application of extra HL produced significantly higher microtensile bond strength and lower nanoleakage values than the control group for both adhesives (p = 0.0001). In all cases, sound dentin showed higher microtensile bond strength and lower nanoleakage values than eroded dentin (p = 0.000001). An extra HL increased the bond strength and reduced nanoleakage in eroded dentin after two-years of storage.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...